The FP range of flameproof rod-type immersion heaters is a highly adaptable solution that can be customised to suit the process requirements of our clients, and are suitable for heating all types of process mediums which are non-corrosive to the materials of construction, and carry multiple approvals for global supply.
The FP rod-type immersion heater range is certified for use in hazardous areas where the atmosphere is classified as a Zone 1 or 2 (IIA, IIB, IIC) gas group, or a Zone 21 or 22 (IIIA, IIIB, IIIC) dust group.
Model | FP4 | FP6 | FP8 | FP10 | FP12 |
---|---|---|---|---|---|
Min Flange Size (Ins) | 3 | 6 | 8 | 10 | 12 |
Min Flange Size (mm) | 75 | 150 | 200 | 250 | 300 |
Max Cable Entries | 1 off M25 & 1 off M20 | 1 off M32 & 2 off M25 | 2 off M25 & 1 off M40 | 2 off M32 & 1 off M25 | 3 off M32 & 1 off M20 |
Max Elements w/o Standoff | 6 | 15 | 21 | 39 | 54 |
Certifications | ATEX / IECEx II 2 G/D Ex d IIC T1 to T6 Gb Zone 1 and 2 ATEX / IECEx Ex tb IIIC T450°C to T85°C Db Zone 21 and 22 (IP66) CSA (CEC/NEC) Class I, Div 1, Groups A, B, C, D; T1 to T6, Enclosure Type / NEMA 4 or 4X CSA (CEC) Ex d IIC; T1 to T6 Gb, IP66 (CAN) CSA (NEC) Class I, Zone 1, AEx d IIC; T1 to T6 Gb, IP66 (USA) CU TR (EAC), KGS, CNEx, CCOE (CCEs), Inmetro |
---|---|
Enclosure | Mild steel or 316 stainless steel, external and internal earths, screwed terminal cover, finished in epoxy paint (if required) |
Elements | A choice of rod-type elements comprising of 80/20 nickel chrome resistance wire, compacted in high purity magnesium oxide insulating powder and encased in either Incoloy or stainless steel sheath, secured by compression fittings, brazing or welding, depending upon the process application |
Controls | Heater over-temperature protection is fitted as standard (optional process temperature sensing devices can be incorporated in the form of thermostats, RTD's or thermocouples) |
Mounting | Any threaded NPT or BSP boss, or flange in any material, can be specified within the limits of the design parameters; heater terminal box can be either 'direct-on' or 'stand-off', depending on process temperature |
Rating | To suit process requirements within the design and certification parameters |
Voltage | Any electrical supply up to 690V (600V CSA) |